Membrane fouling during ultrafiltration of wastewaters from car washes

dc.contributor.authorGryta, Marekpl_PL
dc.contributor.authorWoźniak, Piotrpl_PL
dc.contributor.organizationZachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydział Technologii i Inżynierii Chemicznejpl_PL
dc.contributor.organizationZachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydział Technologii i Inżynierii Chemicznejpl_PL
dc.date.accessioned2024-11-27T18:14:35Z
dc.date.available2024-11-27T18:14:35Z
dc.date.issued2024-05-20
dc.description.abstractThe commercial ultrafiltration PVDF tubular membranes (FP100) were applied for separation of effluents generated during car washing. Using a 50-75% water recovery coefficient allowed to obtain over 60% rejection of COD, and obtain the high-purity permeate (0.3 NTU). However, significant flux decline was caused by a severe membrane fouling. The tubular polyvinylidenefluoride membranes of 100 kDa were obtained from PCI (Poland). The tube inner diameter was 12.5 mm. Wastewater generated from a manual car wash was used for ultrafiltration tests. Wastewater sample collected from the settling tank with a turbidity of 215 NTU contained over 300 mg/L of suspended solids. In addition to the pollutants removed from the cars, it contained surfactants used for washing (120 mg/L), and the determined COD value was 2200 mg O2/L. The transmembrane pressure (TMP) was maintained at 0.05-0.3 MPa, and the feed flow velocity over the membrane was equal to 1 m/s. After completion of UF process, the membranes were rinsed with deionised water and cleaned with alkaline (pH>11) and acid solutions.en
dc.description.sponsorshipMinisterstwo Edukacji i Naukipl_PL
dc.identifier.citationGryta, M., Woźniak P. (2024). Membrane fouling during ultrafiltration of wastewaters from car washes. [Poster]. https://hdl.handle.net/20.500.12539/2114pl_PL
dc.identifier.projectNdS/538617/2021/2022
dc.identifier.urihttps://hdl.handle.net/20.500.12539/2114
dc.language.isoen
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectultrafiltrationen
dc.subjectfoulingen
dc.subjectcar washingen
dc.titleMembrane fouling during ultrafiltration of wastewaters from car washesen

Pliki

Oryginalne pliki
Teraz wyświetlane 1 - 1 z 1
Ładowanie...
Miniatura
Nazwa:
Slow 24 UF fouling poster.pdf
Rozmiar:
1.41 MB
Format:
Adobe Portable Document Format
Licencja
Teraz wyświetlane 1 - 1 z 1
Brak miniatury
Nazwa:
license.txt
Rozmiar:
1.13 KB
Format:
Item-specific license agreed upon to submission
Opis: